Flapless Extraction Socket Healing Around an Immediate Implant Placed into a Mandibular Molar Site Without the Use of Regenerative Materials: A Case Report
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 36 , Issue 2
March/April 2016

Pages e26–e32


Flapless Extraction Socket Healing Around an Immediate Implant Placed into a Mandibular Molar Site Without the Use of Regenerative Materials: A Case Report


Daniel D. Gober, DDS/Matthew J. Fien, DDS


PMID: 26901307
DOI: 10.11607/prd.2516

The aim of this case report is to expand on previous studies of flapless immediate implant placement in sites with a large gap distance, without the application of regenerative materials. In this case report, an immediate implant was placed in a fresh molar extraction site with a large gap distance from the implant surface to the socket walls without the use of a bone graft, membrane, or coronal flap advancement for primary closure. Clinical healing was consistent with spontaneous extraction socket healing. Uncovery at 3 months revealed complete socket fill and secondary stability of the implant. After 2 years and 2 months, bone levels remain stable. This case report demonstrates the natural healing potential of an extraction socket, which can provide sufficient bone healing and dimensional stability for implant osseointegration and a functional restoration.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help